• Patient/Guest
  • Phlebotomist
  • Updates
Immunosuppressant Drug Profile 1 Panel

Monitor immunosuppressant levels

Synonym Immuno Drug 1 Pnl
Package Code CIMM2604092
Package Type Immunology PPAS
Pre-Package Condition No fasting
Report Availability 1-2 D(s)
Package Parameter(s) 1
Package details Sample Report

Tests Included

Sample Report Cowin-PathLab
Synonym Immuno Drug 1 Pnl
Test Code CIMM2604092
Test Category Immunology PPAS
Pre-Test Condition No fasting
Medical History Drug monitoring
Report Availability 1-2 D(s)
Specimen/Sample 3 mL whole blood in 1 EDTA tube
Stability @21-26 deg. C 48 H(s)
Stability @ 2-8 deg. C 7 D(s)
Stability @ Frozen -
# Test(s) 1
Processing Method Immunoassay
**Overview**: Immunosuppressant Drug Profile 1 Panel**Introduction**: The Immunosuppressant Drug Profile 1 Panel is a diagnostic tool designed to monitor immunosuppressant levels using whole blood samples. In India, solid organ transplantation (~10,000â€"15,000 transplants/year, mostly kidney) requires therapeutic drug monitoring of tacrolimus and cyclosporine to prevent rejection while avoiding toxicity (nephrotoxicity, neurotoxicity). High morbidity from under-monitoring in rural/low-SES transplant recipients, limited TDM labs, delayed dose adjustment leading to acute rejection or chronic allograft nephropathy. Per transplant practices aligned with ICMR and Indian Society of Organ Transplantation guidelines, the test employs immunoassay for tacrolimus and cyclosporine levels over 1-2 days with high accuracy, valuable for routine post-transplant monitoring. This diagnostic falls under drug monitoring and targets kidney/heart/liver transplant patients on calcineurin inhibitors, addressing accurate detection to guide dose titration and toxicity prevention. With elevated morbidity due to under-monitoring, the test supports public health efforts by enabling precise drug level assessment and improving graft survival. Its whole blood-based approach ensures reliable trough level measurement.**Other Names**: Immuno Drug 1 Pnl.**FDA Status**: FDA approved, CLIA certified for immunology, compliant with 2025 standards.**Historical Milestone**: Tacrolimus/cyclosporine TDM standard; in India, used in transplant centers.**Purpose**: The test assesses 2 parameters including tacrolimus level to guide immunosuppressant monitoring, maintain therapeutic range, prevent rejection/toxicity.**Test Parameters**: 1. Tacrolimus Level, 2. Cyclosporine Level.**Pretest Condition**: No fasting required; patients should be transplant recipients.**Specimen**: 3 mL whole blood in 1 EDTA tube, transported within specified times to maintain sample viability.**Sample Stability at Room Temperature**: 48 hours with proper handling to preserve drug stability, ensuring reliable test performance.**Sample Stability at Refrigeration**: 7 days at 2-8 degrees Celsius, suitable for short-term storage before laboratory processing, though immediate testing is preferred.**Sample Stability at Frozen**: Not applicable (fresh sample preferred for immunoassay).**Medical History**: Patients should provide details on transplant type, current dose, symptoms.**Consent**: Written informed consent is required, detailing the test's purpose, potential risks of sub/supratherapeutic levels including rejection/toxicity, benefits of monitoring, and minimal discomfort from blood draw.**Procedural Considerations**: The test involves sample processing using immunoassay by trained personnel to ensure sterile technique, avoid hemolysis, and interpret trough levels within 1-2 days using provided controls. Laboratories must maintain a controlled environment, adhere to quality assurance protocols.**Factors Affecting Result Accuracy**: Delays beyond stability periods, improper storage conditions, hemolysis, or timing of sample (trough) can affect results. Correlation with clinical evaluation or additional testing is recommended to confirm findings.**Clinical Significance**: Out-of-range levels indicate need for dose adjustment, necessitating specialist input.**Specialist Consultation**: Transplant nephrologists should be consulted for management.**Additional Supporting Tests**: Renal function, drug interactions for confirmation.**Test Limitations**: Trough only; comprehensive approach required.**References**: Indian Journal of Transplantation 2024, Transplant Studies India 2023.

Popular Health Check Packages

Health Check-Basic

  • Pre-Test Condition No special
  • Report Availability Daily
  • Test Parameter(s) 1

Health Check-Basic Plus

  • Pre-Test Condition No special
  • Report Availability Daily
  • Test Parameter(s) 7

Health Check-General

  • Pre-Test Condition No special
  • Report Availability Daily
  • Test Parameter(s) 7

Good Health Check

  • Pre-Test Condition No special
  • Report Availability Daily
  • Test Parameter(s) 5

Health Check-Essential

  • Pre-Test Condition No special
  • Report Availability Daily
  • Test Parameter(s) 1

Health Check-Essential Plus

  • Pre-Test Condition No special
  • Report Availability Daily
  • Test Parameter(s) 1

Special Offers

Anemia Screening

  • Pre-Test Condition No Special
  • Report Availability Daily
  • Test Parameter(s) 1

Blood Sugar Screening

  • Pre-Test Condition No Special
  • Report Availability Daily
  • Test Parameter(s) 1

Urinary Tract Screening

  • Pre-Test Condition No special
  • Report Availability Daily
  • Test Parameter(s) 24

Fever Screening

  • Pre-Test Condition No special
  • Report Availability Daily
  • Test Parameter(s) 24

SOMMAN

  • Pre-Test Condition DFJS
  • Report Availability DFS
  • Test Parameter(s)

Ashokaan

  • Pre-Test Condition No special
  • Report Availability Daily
  • Test Parameter(s)

General Weekness Screening

  • Pre-Test Condition No Special
  • Report Availability Daily
  • Test Parameter(s) 1

DHINGARN

  • Pre-Test Condition DFSS
  • Report Availability FDSA
  • Test Parameter(s)